Measurement | Performance |
---|---|
Material | 3-Layer Polypropylene Sheet (Spun Bonded Polypropylene Layer, Microporous Polypropylene Film, Spun Bonded Polypropylene Layer) |
Mass | 100gsm |
Width | 1m (3ft 3in) or 1.5m (4ft 11in) |
Length | 20m (65ft 7in) or 50m (164ft 1in) |
Maximum tensile force MD / CMD (N/50mm) | 260 / 170 |
Elongation MD / CMD (%) | 50 / 80 |
Resistance to Tearing MD / CMD (N) | 120 / 140 |
Resistance to penetration of air (m3/m2.h.100Pa) | < 0,02 |
Fire Class | E |
Water Resistance Class | W1 |
Compatibility | Suitable for both fully supported and unsupported warm, cold and hybrid, tiled or slate pitch roofs. Can be used with sarking boards. |
Certification | BS5534.2014 Annex A, Type LR Underlay to BS5250, BBA 10/4753, NSAI, CE |
Grafter 100 Breather Membrane Roofing Felt from Easy-Trim
Reliable lightweight vapour permeable membrane!
Lightweight hybrid breathable roof underlay provides excellent performance, whilst being flexible and only 100gsm. BBA certified and suitable for both fully supported and unsupported installations in tiled or slate pitch roofs.
The Grafter 100 is a 3-layer micro porous breather membrane, which features a microporous film that is thermally bonded between two spun-bonded polypropylene layers. Allows the roof to breathe, so eliminates condensation, whilst providing secondary protection against rainwater ingress. Easy-Trim breather membranes improve energy efficiency and minimise the wind uplift that can loosen slates and tiles.
Features & Benefits
- Protects roof slate and tile - reduces wind uplift
- Reduces condensation in roof - highly vapour permeable
- Driven rain and snow protection - second line of defence
- Highly versatile - use on warm, cold and hybrid roofs
- Flexible yet strong - good tensile tear strength
- UV stable for 3 months - protection during construction
- Quality you can trust - independently tested
- Superior water resistance - protective polypropylene top layer
- Printed with brand and cutting grid - easier to identify and fit
- Choice of roll size - 1m or 1.5m widths and 20m or 50m length
National Wind Zone Suitability
New builds must comply with British Standard for Tiling and Roofing (BS5534) Annex A, with breather membranes tested against wind uplift, and their suitability for use across the 5 national wind zones.
Batten Gauge | Wind Zone Suitability | |||||
---|---|---|---|---|---|---|
Gauge | Lap | 1 | 2 | 3 | 4 | 5 |
<=345mm | Batten | Y | ||||
<=250mm | Batten | Y | Y | T | Y | Y |
<=345mm | Taped | Y | Y | Y | Y | Y |